6.6.1 Macro Settings Tab
This tab provides a way to execute/edit the settings for the unit’s rst
8 macro buttons. These macros can be executed by activating triggers
1~8 (via the Trigger or Trigger Button ports) as well as via the WebGUI or
Telnet.
1) Macro Buttons: Press any of these buttons to activate the macro
currently stored within it. Hovering the mouse over a button will list its
current macro contents. Click on the edit icon ( ) to edit each button’s
macro.
There are 8 macros dened by default for testing the System Control
Center’s functionality. Click on macros 1~8 to demonstrate various
functions. The presets functions are:
Macro 1: Sequentially close relays 1 through 4 with a 100ms delay.
Macro 2: Sequentially open relays 1 through 4 with a 100ms delay.
Macro 3: Sequentially toggle the state of Relays 1 through 4 with a
100ms delay.
Macro 4: Sequentially send IR signals from emitters 1 through 4
with a 100ms delay.
Macros 5~8: Send a sample text string over the COM port with a
100ms delay afterwards.
2) Macro Edit: Click on any button’s edit icon (
) to edit that button’s
macro. The Macro Edit window displays the full contents of the macro
including it’s name as well as each command’s communication
interface to use with its associated parameters, delay time
before executing the next command, and conditional execution
requirements. The order of command execution is from top to bottom.
When you have nished editing the macro click on “Save Change”.