9
6.2 Rear Panel
IR IN
TRIGGER IN
COMPORT
SERVICE
CONTROL
(POE)
POWER
DC 5V
1
5V
2
3
4
5
GND
6
7
8
54321
RXD
RS232
RS422
RS485
TXD GND
RX+ RX- TD-TD+ GND
TD-TD+ GND
1 2 3 4 5 6
1
DC 5V: Plug the 5V DC power adapter into the unit and connect it to
an AC wall outlet for power.
Note: If the unit is being powered by PoE then this connection is optional.
2
CONTROL (PoE): Connect directly, or through a network switch, to
your PC/laptop to control the unit via telnet/WebGUI.
3
USB: This slot is reserved for rmware update use only.
4
COMPORT: Connect to the device you wish to control via a 3(or 5)-pin
adapter cable to send RS-232/422/485 commands from the unit. Baud
rates up to 115200 are supported. For pin connection details please
refer to the graphic above.
5
TRIGGER IN: Connect to any device with trigger or switch
functionality such as window security alarms, motion detectors, door
switches, etc. Each of the 8 trigger inputs will activate the associated
macro when triggered. A minimum of 5V DC is required to activate the
trigger. For pin connection details please refer to the graphic above.
6
IR IN: Connect to the provided IR Extender to allow IR control of the
unit or for learning IR commands. Ensure that the remote being used
is within direct line-of-sight of the IR Extender.
Note: For additional IR learning details please refer to section 6.7.3.