22Curtis Instruments enGage
®
VII Manual
EMC Specications continued
Immunity
Designed to meet the following:
• EN 61000-4-2 Electro-Static Discharge
• EN 61000-4-3 Radiated RF Immunity
• EN 61000-4-4 Electrical Fast Transients
• EN 61000-4-6 Conducted RF Immunity
• EN 61000-6-2 Immunity for industrial environments
Compliance
RoHS 2: enGage VI and enGage VII.
4.0 TROUBLE-SHOOTING
GENERAL
Problem / Possible Cause
No Display –
V+ (keyswitch) voltage not present at J1–1, J1-3.
Battery voltage too low. Battery terminals not connected.
Display Too Dark/Light –
LCD backlight not adjusted correctly.
BDI FUNCTION
Problem / Possible Cause
No Display –
Terminals not connected.
Improper voltage – Check B+ / B- is connected to proper pins (see tables earlier in this manual).
Stays At FULL –
Instrument voltage range selected does not match battery voltage.
V+ connected to wrong terminal.
BDI information coming from CAN network, CAN network value not correct.
Will Not Reset –
Instrument voltage does not match battery voltage.
Battery not fully charged, battery may be defective.
BDI information coming from CAN network, CAN network value not correct.