Curtis enGage VI handleiding
Handleiding
Je bekijkt pagina 14 van 24

14Curtis Instruments enGage
®
VI Manual
2.4 CANBUS OPTION
CANbus pins CAN TERM 1 & CAN TERM 2 can be connected together to provide a 120 Ohm
CANbus termination.
Isolated CANbus Option
The optional isolated CANbus interface allows the enGage
®
VI to be connected to a CANbus system
that is referenced to a separate isolated ground system. The isolated CANbus circuitry has its own
power supply and provides galvanic isolation from the rest of the unit’s circuitry. The ground for the
isolated power supply is connected to J1-10.
The specication for the isolated CANbus option is detailed in Table 15 below.
2.5 HOUR METER
The enGage
®
VI keeps track of four hour meters, any of which can be resettable if this option is
selected at time of unit purchase. Optional resettable hour meters may be reset via the menu system.
Each hour meter may be programmed to accumulate time based on a switched input, keyswitch,
CANbus data, etc. More sophisticated logic can be programmed to handle various conditions.
Hour meter range is 99,999.9
2.6 MAINTENANCE MONITOR
The enGage
®
VI keeps track of three count-down maintenance monitors. Each maintenance monitor
can be programmed to activate based on a switched input, keyswitch, CANbus data, etc. More
sophisticated logic can be programmed to handle various conditions. Each maintenance monitor can
be typically reset via the menu system. Maintenance monitor range is 999. Note that maintenance
monitors are set using whole number amounts (no decimal point shown). However, once set they will
show elapsed time remaining with tenths of an hour resolution.
2.7 ODOMETER
The enGage
®
VI keeps track of three odometers, any of which can be resettable. The odometer function
requires vehicle speed data. This data may come from a frequency input or the CANbus. The units can
be displayed as miles or kilometers. The user may switch between miles and kilometers and set the
pulses / mile or pulses / km constant via the menu system. Each odometer may be a cumulative type or
a “trip” odometer which is resettable. Odometer range is 999,999.9 (units as necessary).
2.8 AUDIBLE ALARM
The enGage
®
VI includes a PCB mounted audible alarm that has a xed frequency and volume level of
2,300 Hz, 80 dB respectively. On cased products (model 3601T), sound emits from a vent in the rear of
the unit. The alarm can be programmed to activate with one of the switch inputs, CANbus data, when
a specied gauge element reaches a certain value, when a sender input reaches a certain value or
when an internal calculation reaches a certain value. More sophisticated logic can be programmed to
handle various conditions.
Table 15 Isolated CANbus Specication
Parameter Value Units Conditions
Dielectric Insulation Voltage 2500 V rms 1 minute duration