5 — MONITOR PARAMETERS
pg. 45
Return to TOC Curtis Model 3301T – August 2022
OUTPUT MENU
e following table describes the parameters on the Output menu.
OUTPUT MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES DATA SIZE ACCESS LEVEL DESCRIPTION
PWM Duty
0x6700:00
0.0–100.0%
0–1000
16-bit Field
Intermediate
Indicates the PWM percentage when pin 8 is
congured as a driver.
Current
0x66E0:00
0–1000mA
0–1000
16-bit Field
Intermediate
Indicates the current sunk when pin 8 is congured
as a driver.
TEMPERATURE MENU
e Temperature menu contains the Internal Temperature parameter:
TEMPERATURE MENU
PARAMETER
CAN INDEX
VALUES
RAW VALUES DATA SIZE ACCESS LEVEL DESCRIPTION
Internal Temperature
0x6618:00
–50°C to +120°
–500 to +1200
16-bit Field
Intermediate
Indicates the temperature of the LCD.