2 — INSTALLATION AND WIRING
pg. 9
Return to TOC Curtis 1355 CANopen Soft Starter Module Manual – September 2020
1355-X101 Digital Inputs (pins 1, 6, 10, 11, 13, 14)
e six digital inputs can be programmed as remote inputs from CAN or as command switches via
a programmer or over the CAN bus (SDO).
Input voltage range:
1355-4101 0–60 V
1355-5101 0–80 V.
Sink current:
1355-4101 3 mA at 60 V
1355-5101 3 mA at 80 V.
High level threshold: >10 V.
Pin 14 can be used as a digital input or as an interlock. When it is used as an interlock, this pin
provides a second enable input such as a seat switch, a pedal switch, or a charger inhibit.
J2-4
J2-3
J2-2
J2-9
J2-1
J2-6
J2-10
J2-11
J2-13
J2-14
KEY SWITCH
FROM MAIN
CONTROL BOARD
MAIN COIL
CAN PORT
MAIN DRIVER
KSI
DIGITAL INPUT 1
DIGITAL INPUT 2
DIGITAL INPUT 3
DIGITAL INPUT 4
DIGITAL INPUT 5
DIGITAL INPUT 6
(INTERLOCK)
CAN H
CAN L
RIGHT BRUSH
LEFT BRUSH
SIDE SWEEP
VACUUM 1
VACUUM 2
SWITCH 1
SWITCH 2
SWITCH 3
SWITCH 4
SWITCH 5
SWITCH 6
DIGITAL INPUT 1
BATTERY
1355-X101
J2-5
J2-8
J2-7
J2-12
SERIAL PORT
(4-pin Molex)
4
3
1
2
+15V
Tx
Rx
GND
M
POWER
FUSE
M
M
M
M
B+
M1
M2
M3
M4
M5
B-
MAIN
CONTACTOR
Figure 3b
Basic wiring diagram, Curtis 1355-X101 module.