Curtis 1205M handleiding

40 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 40
2 — INSTALLATION & WIRING: Connections
High current connections
These controllers have four high-current busbars: B+, B-, A2, and M-. The
busbars are tin-plated solid copper.
Table 1 High Current Connections
B+ Battery+ and motor armature. (plug diode -)
B- B-.
A2 Motorarmatureandeld(plugdiode+).
M- Motoreld(controlleroutput).
Cables used for the battery and motor connections must be heavy enough to
carry the high current required. A minimum size of 25 mm
2
(#4 AWG) is
recommended.
Connections to the controller busbars should be made with lugs suitable
for the cable used, fastened by M8 bolts and nuts. When tightening the bolts,
two opposing wrenches should be used. Failure to use the double-wrench
technique could cause undue strain to be placed on the internal connections,
and could also result in cracked seals around the busbars.
Low current connections
These controllers have five low-current connections: four 6.35 mm push-on
terminals (J1, J2, J3, and J5), and one 4-pin connector (J4).
Table 2 Low Current Connections
J1 Keyswitch.
J2 Wire 1 of 2-wire throttle; Pot High of 3-wire or ITS throttle.
J3 Wire 2 of 2-wire throttle; Pot Wiper of 3-wire throttle;
Pot Low of ITS thottle; or electronic throttle input.
J4 4-pin connector: see Table 3.
J5 Reverse signal output / main contactor coil driver.
CONNECTIONS
The controllers connectors are all conveniently located on one end:
For the control wiring, 0.75 mm
2
(#18 AWG) vinyl insulated stranded wire
is recommended.
A2
M–
B– B+
J1
J2
J3
J4
J5
Curtis 1204M/1205M/1209M/1221M Manual
5

Bekijk gratis de handleiding van Curtis 1205M, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkCurtis
Model1205M
CategorieNiet gecategoriseerd
TaalNederlands
Grootte4663 MB