3 — PROGRAMMABLE PARAMETERS: Voltage Parameters
VOLTAGE MENU
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Battery Voltage 1 – 6 Setthisparametertomatchthebatterypackofyourvehicle.
1 = 12 V
2 = 24 V
3=36V
4 = 48 V
5=60V
6=72V.
Under Voltage Cutback 68  – 100% Thecontroller’scircuitryrequiresaminimumbatteryvoltagetofunction
properly.Whenbatteryvoltagedrops,reducingthecontroller’soutput
tothemotorallowsthebatterytorecover.TheUnderVoltageCutback
parameter sets the threshold voltage below which controller output will
start to be reduced.
The programmed value is a percentage of the battery voltage.
Under Voltage Cutback Rate 0 – 110A TheUnderVoltageCutbackRatedetermineshowquicklythecontroller
output will be reduced when battery voltage falls below the programmed
UnderVoltageCutbackthreshold.
The programmed value is the amount the current will be reduced
for every 0.4 V the battery voltage decreases.
Larger values represent faster reduction of controller output.
SettingUnderVoltageCutbackRate=0meanstherewillbeno
undervoltagecutback.
Under Voltage Cutoff 67 – 100% TheUnderVoltageCutoffparametersetsthevoltageatwhichcontroller
output will be cut off completely.
The programmed value is a percentage of the battery voltage. The
Under Voltage Cutoff parameter can only be set to values smaller (lower)
thantheprogrammedUnderVoltageCutback.