Crown Verity IGM-GH handleiding

69 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 51 van 69
Page 51 of 69
If the flames are mostly yellow or are noisy and lift off the burner ports, rotate the air
shutter to progressively reduce the amount of air entering the venturi.
Continue to
close the air shutter until the flame no longer lifts from the burner. For a sooty flame,
progressively open the air shutter until the flame burns cleanly.
Once adjusted to a stable flame that burns cleanly and does not lift, turn the grill control
knob to the OFF position. Tighten the lock screw. Re-light and confirm the adjustment is
good. Once confirmed, replace the radiant and burner tube, place the pin back into hole at
the back of the burner tube to secure the radiant and burner tube in place, then replace
the faceplate. For appliances equipped with the lighting option, ensure that all
connections are made to the switches and bezels.
FIGURE 19. SHUTTER ADJUSTMENT

Bekijk gratis de handleiding van Crown Verity IGM-GH, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkCrown Verity
ModelIGM-GH
CategorieNiet gecategoriseerd
TaalNederlands
Grootte14904 MB