2. Screw in leveling legs
Leveling leg with diamond
marking.
Leveling leg without diamond
marking
Using a wrench and tape measure, screw leveling legs into
leg holes until bottom of foot is approximately 1/2" (13 mm) to
1
1
/
2
" (38 mm) from bottom of the dryer.
For leveling legs with the diamond marking:
Screw legs into leg holes by hand. Use a wrench to finish
turning legs until diamond marking is no longer visible.
Place a carton corner post from dryer packaging under each
of the two dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
Electrical Installation – U.S.A.
WARNING
Fire Hazard
For power supply cord, use a new UL listed 30 A power
supply cord.
For direct wire, use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Connect ground wire (green or bare wire) to green
ground connector.
Connect remaining 2 supply wires to remaining 2
terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or electrical
shock.
1. Disconnect power
2. Remove terminal block cover
NOTE: Your terminal block cover may be in a different
location.
Remove hold-down screw and terminal block cover.
3. Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R): Refer to “4-Wire Power
Supply Connection”. Then, go to “Venting
Requirements.”
Power supply cord 3-wire receptacle
(NEMA Type 10-30R): Refer to “3-Wire Power
Supply Connection”. Then, go to “Venting
Requirements.”
4-wire direct connection: Go to “Direct Wire
Strain Relief,” then “4-Wire Direct Wire
Connection,” then, go to “Venting
Requirements.”
3-wire direct connection: Go to “Direct Wire
Strain Relief”, then “3-Wire Direct Wire
Connection,” then, go to “Venting
Requirements.”
NOTE: If local codes do not permit connection of a cabinet-
ground conductor to neutral wire, go to “Optional 3-wire
Connection.” This connection may be used with either a
power supply cord or a direct wire connection.
Power Supply Cord Connection
Power Supply Cord Strain Relief
1. Attach power supply cord strain relief
Remove the screws from a 3/4" (19 mm) UL-listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole below the terminal block opening (B)
so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.