Failure Probable Cause Fix
1. Pans do not t perfectly in trans-
port angles
1a. Misalignment 1a. Add or remove shim kit.
2. Power light o, cabinet does
nothing
2a. Battery not charged. 2a. Charge battery.
3. Thermometer value is ashing. 3a. Cabinet is outside normal temperature. 3a. Allow cabinet to come to temp.
Cabinet is Not Cooling:
Failure Probable Cause Fix
1. Compressor not operating.
1a. Sensor issue. 1a. Fix or replace.
1b. Wiring issue. 1b. Fix or replace.
1c. Compressor overheated. 1c. Wait to cool.
1d. Component failure. 1d. Replace.
2. Evaporator fans not operating.
2a. Door open. 2a. Close door.
2b. Wiring issue. 2b. Fix or replace.
2c. Door switch failure. 2c. Fix or replace.
2d. Evaporator fan failure. 2d. Replace.
3. Condenser fan not operating.
3a. Wiring issue. 3a. Fix or replace.
3b. Condenser fan failure. 3b. Replace.
4. Refrigerant loss. 4a. Leak. 4a. Check system for leaks, recharge.
TROUBLE-SHOOTING GUIDE
Unit Condition:
Unit is plugged in. Switch is ON.
NOTES:
1. For replacement of the electrical parts, refer to our list of authorized service centers (FL-1400).
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE