(5) NOTICE OF INSTALLATION
1. Before installation, please ensure the area is clean to avoid suction of the
remaining bits of broken wood and dust.
2. It cannot share the same air ventilation tube with other appliance such as gas
tube, warmer tube, and hot wind tube.
3. The bending of ventilation tube should be≥120°, parallel or above the start
point and should be connected to the external wall.
4. After installation, make sure that the extractor is level to avoid grease
collection at one end.
(6) SAFETY WARNING
Never let the children operate the machine.
The cooker hood is for home use only, not suitable for barbecue, roast shop and other commercial
purpose.
The cooker hood and its filter should be clean regularly in order to keep in good working condition.
Clean the cooker hood according to the instruction manual and keep the unit from danger of burning.
Forbid the direct baking from the gas cooker.
Please keep the kitchen room a good convection.
Before connecting this appliance check that the power supply cord is not damaged. A damage supply
cord must be replaced by qualified service personnel only.
There shall be adequate ventilation of the room when the range hood is used at the same time as
appliances burning gas or other fuels
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning
gas or other fuels
Regulations concerning the discharge of air have to be fulfilled.
Do not flame under the range hood.
The range hood is not intended to be installed over a hob having more than four hob elements
This appliance is not intended for use by persons ( including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
The air must not be discharged into a flue that is used for exhausting fumes from appliances burning
gas or other fuels.
When the range hood and appliances supplied with energy other than electricity are simultaneously
in operation, the negative pressure in the room must not exceed 4 Pa ( 4 x 1 0 - 5 bar) .
CAUTION: Accessible parts may become hot when used with cooking appliances.
Electrical Shock Hazard
Only plug this unit into a properly earthed outlet. If in doubt seek advice from a suitably qualified
engineer.