Cooking Performance Group 351COHD3A handleiding

14 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 5 van 14
www.cookingperformancegroup.com
5
User Manual
Installation
These units are designed for commercial use and not for household use.
Installation must conform to all applicable codes. Improper installation will void the
manufacturers warranty.
Do not obstruct or reduce the air ow rate of the natural ventilation openings on the
oven or the vent located at the rear of the oven.
Discontinue use if power cord or electrical wires are frayed or worn.
This product conforms to UL-197 standards and is required to be installed under a
ventilation hood in accordance with all applicable codes.
Combustiable Clearance Requirements: 20" Sides, 28" Back
Non-Combustiable Clearance Requirements: 2" Sides, 2" Back
Installation Instructions
The place of installation must be indoors, well ventilated, and the ambient temperature must be at least
40 degrees Fahrenheit. The unit is required to have at least 2" of clearance on the sides and back from
non-combustible surfaces, or at least 20" and 28" of clearance on the sides and back, respectfully, from
combustible surfaces. Ensure that all four legs are installed correctly before the operation of this oven.
The unit is required to be installed on a non-combustible surface with 4" legs, or a combustible oor with
a stand. For full-size models, level unit by adjusting the (4) feet which have an adjustment of 1¾" for
accurate leveling.
This product conforms to UL-197 standards and requires it to be
under an exhaust hood. A vertical distance of not less than 48"
shall be provided between the top of the appliance and lters
or any other combustible material. Exhaust installation must
conform to applicable local codes.
Do not obstruct or reduce the air ow rate of the natural
ventilation openings on the oven or the vent located at the rear
of the oven. To ensure proper ventilation and clearance, the
provided spacer is required to be installed.
The spacer must be installed by screwing (2) self-threading
screws on the back of the unit immediately below the cooling
fan.
NOTE: For Oven Stacking Instructions, please see page 14.
WARNING: DO NOT OBSTRUCT THE VENT OR COOLING FAN LOCATED AT THE REAR OF
THE OVEN.