WORKTOP/UNDERCOUNTERS & SANDWICH UNITS
OPERATIONS MANUAL
Air supply to the condensing unit is critical. Restricting airflow
places excessive heat load on the unit, adversely affecting its
operation and may cause premature failure. The condenser coil
must be kept clean and free from obstruction. After-market air
filters or flour filters should not be used, because they hinder
airflow, especially if they are not replaced frequently. Contact our
factory Service Department for more information.
For optimum performance, all models should be installed on
casters or legs (see “Installing Casters” or “Legs”) with a
minimum 3” on each side and back of cabinet (see Figure 2).
This spacing will provide sufficient room for proper air circu-
lation and clearance to access components for cleaning and
maintenance. If any of the these conditions cannot be met, the
installer should provide special venting or air ducts, as required.
Your model has also been designed to operate sufficiently
without legs or casters and directly on the floor as long as a
minimum clearance of 8” is provided from the rear venting
louvers and the rear wall (see Figure 2). Cabinet side clearance
is not required when mounting your model directly on the floor,
without legs or casters. If any of the above conditions can not be
achieved, the installer should provide special venting or air sup-
ply ducts, or a Front-Breather Kit (see “Optional Accessories”)
can be ordered by contacting the factory.
“UC” series models and units provided with the Front-Breather
Option do not require any clearance around the the sides or
back of the cabinet, since they take in and exhaust air under the
cabinet and through the front grill, under the door. The air flow
under the cabinet and through the front grill cannot be restricted.
(see “Front Breather Kit” under “Optional Accessories”).
FIGURE 2: Minimum Clearance Dimensions for Optimum Conditions
05/13/10
IMPORTANT NOTE: Do not under any circumstances, lay
your new model on its front or sides. For a brief period
of time, you may lay the cabinet on its back, but only
when its properly blocked so as not to crush the louvered
venting panel and also to allow provision for your hands,
in order to set it in its upright position without damaging
the cabinet. Do not plug in and operate model for at
least three (3) hours after cabinet is set upright from
being on its back as this can damage the compressor.
INSTALLATION AND LOCATION
Before moving the cabinet to its final point of installation, mea-
sure all doorways or passages to assure clearance. If additional
clearance is needed, you can remove the cabinet doors (see
“Removal of Doors and Door Adjustment”) and lids (when
equipped) (see “Removing Lid and Hood”).
VENTILATION
The final location site of your air cooled refrigerator or freezer
must provide a sufficient quantity of cool, clean air. All refrigera-
tion systems operate more efficiently and trouble-free with cool,
dry air circulation. Avoid locations near heat and moisture gen-
erating equipment including ovens, fryers, dishwashers, steam
kettles, etc. Do not install in direct sunlight (where temperatures
may exceed 100°F) or in an unheated area (where temperatures
may drop below 55°F).