OPERATIONS MANUAL      
                                  REFRIGERATED BASES & PIZZA PREP TABLES
IMPORTANT NOTE: It is extremely important that your 
cabinet is perfectly level for proper operation. If it is not 
level, the following adverse conditions may occur:
1.  The door(s) will not be properly aligned and 
     consequently will not provide a good seal. 
2.  Your unit may run excessively.
3.  An excessive amount of ice will accumulate inside 
     the cabinet, around the door opening(s) and on the 
     finned evaporator coil. If allowed to continue, ice will
     eventually block the coil and the unit will fail. This 
     can result in the loss of all food stored in the cabinet. 
4.  Defrost water will fail to drain properly and will 
     overflow the evaporator coil drain pan and into the
     cabinet of both refrigerator and freezer models.
A
OPTIONAL
CASTER SHIM
(CM1-2476)
CASTER
CASTER INSTALLATION
BLOCKS
FIGURE 3A: Casters Must Be Tight to Cabinet Bottom
04/29/10
FIGURE 3: Installing Casters
FLOOR LOADS
The floor at the final location site must be level, free of vibration 
and strong enough to support the total combined weights of 
your new model plus the maximum product load which might 
be placed into it. Keep in mind that all the weight is concentrated 
at the caster or leg locations. To estimate the possible product 
weight, assume that each cubic foot of storage space weighs 
approximately 35 pounds. Multiply 35 pounds by the amount of 
cubic feet in the cabinet to obtain the product load weight. 
For example, a 20 cubic foot refrigerator can hold approximately 
700 pounds of product (35 x 20). Assuming the cabinet itself 
weighs 300 pounds, the total combined weight of cabinet and 
product is approximately 1000 pounds. Therefore, the floor in 
this example must be able to support up to 1000 pounds.
NOTE:  Any equipment placed on your cabinet must be 
included in the floor load calculation. Do NOT overload 
the top of your cabinet by placing extremely heavy equip-
ment on it, or damage can occur, which is NOT covered 
under Warranty. Consult the factory for information on 
the weight load capacity for your specific cabinet. 
INSTALLING CASTERS AND LEVELING
If your new unit is supplied with swivel casters, they will be 
packed in the accessory box that came with your cabinet. 
Casters should be installed only when the cabinet is close to 
its final installation site. To install casters on your new model, 
place wooden blocks along the back, at each end. Tilt the cabi-
net back, using the wood blocks to help hold the cabinet in its 
tilted position. Locate the large threaded holes on the bottom 
of the cabinet and screw the threaded caster studs into the 
mounting holes, closest to the front of the unit. Repeat this 
procedure by tilting the cabinet in the opposite direction and 
installing the remaining casters. Make sure the casters are 
tightened extremely well (see Figure 3 & 3A). If the casters are 
not installed tightly, the cabinet will be unstable and may sway 
or rock, which can damage the cabinet. 
If the height of a caster needs to be raised, shims must be 
installed under the casters which need leveling. Extra large 
washers, available at most hardware or furniture stores, can be 
used to shim casters, or contact the factory for caster shims.
Do not level casters by unscrewing them and leaving 
them loose. This will damage the cabinet and threaded 
holes, voiding your warranty.