• Compliance with national gas regulations shall be observed. Keep ventilation
openings clear of obstruction.
• The appliance shall be stored so as to prevent mechanical damage from
occurring.
• A warning that the appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specified for operation.
• Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry-accredited assessment
authority, which authorises their competence to handle refrigerants safely in
accordance with an industry recognised assessment specification.
• Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent in
the use ofammable refrigerants.
• Please follow the instruction carefully to handle, install, clear, service the air
conditioner to avoid any damage or hazard. Flammable Refrigerant is used
within air conditioner. When maintaining or disposing the air conditioner, the
refrigerant (R32 or R290) shall be recovered properly, shall not discharge to air
directly.
• No any open fire or device like switch which may generate spark/arcing shall be
around air conditioner to avoid causing ignition of the flammable refrigerant
used.
• Please follow the instruction carefully to store or maintain the air conditioner to
prevent mechanical damage from occurring.
• Flammable refrigerant is used in air conditioner. Please follow the instruction
carefully to avoid any hazard. For special information on the type of gas and the
amount,please to the relevant label on the unit itself.
• The appliance shall be stored in a room without continuously operating open
flames (for example an operating gas appliance) and ignition sources (for
example an operating electric heater).
For R290
amount of refrigerant (kg)
4
5
6
7
8
9
10
0.0836 and 0.1045
≥
≥
<
0.1045 and 0.1254
≥
<
0.1254 and 0.1463
≥
<
0.1463 and 0.1672
≥
<
0.1672 and 0.1881
≥
<
0.1881 and 0.2090
≥
<
amount of refrigerant (kg)
11
12
13
14
0.2090 and 0.2299
≥
<
0.2299 and 0.2508
≥
<
0.2508 and 0.2717
≥
<
0.2717 and 0.2926
≥
<
15
0.2926 and 0.3040
≥
<
0.0836
Caution:
Risk of fire/flammable materials
(Required for R32/R290 units only)
05