Assembly/commissioning
Operaon
The AQiX water dosing system is set to the unit of “litres”
ex works.
The instrument is delivered with a standard ½“ hose con-
necon. This can be unscrewed and replaced with a dier-
ent tap connecon, such as with a bayonet coupling.
Standard hose couplings with 1/2“ or 3/4“ hose connecon
can be used as a quick-release or bayonet coupling.
Connect the water hose to the meter. The water hose may
not be pressurised.
Only connect the hose to the hose coupling. No hose may
be connected to the water outlet (7).
IMPORTANT: venng
Aer every connecon made to the water hose, rst make
sure that the air can escape from the instrument.
Press the “START/PAUSE” (12) buon to switch on the
instrument.
Set the display to “0” with the “0.00 - Man.” (10) buon.
Keep holding the “START/PAUSE” (12) buon unl the
water ows out without any interrupon.
Start dosing:
Press the "START/PAUSE” (12) buon to start the metering.
You can interrupt the metering process. Press the "START/
PAUSE” buon to do this. Pressing the buon again starts
the metering process where it was interrupted.
Storing a metering quanty
Frequently used metering quanes can be saved by press-
ing the “M1” / "M2” (8+9) buons. Set the desired quanty
value with the “+” and “-” buon. Then hold “M1” / “M2”
for 2 seconds unl the value in the display ashes. Press
“M1” / "M2” to call up the stored value. It will appear in
the display
Manual metering:
Press the “Man/0.00” buon (10). Then press “START/
PAUSE” (12). The water will run for as long as you hold
down the buon. The dispensed quanty of water is
shown in the display.
Converng the unit of measure:
The water dosing system can be used with three dierent
units of measure: Litres, quarts and US gallons.
To switch between them, hold the “Man/0.00” buon for
5 seconds unl 0_ _ appears in the display. Set the desired
number for the respecve unit of measure using “+” and
“-”. Conrm each digit with the “START/PAUSE” buon.
Finally press Play twice. The instrument switches o and
changes the mode.
Value 100 = litres | 200 = quarts | 300 = gallons
You can hold the instrument in your hand for metering or
hang it on the mixing bucket or on the mixing bucket of a
mixer.
The instrument is hung between the water outlet (7) and
the retaining bracket (6)
Switching on the instrument:
The AQiX water dosing system is switched on using the
“START/PAUSE” (12) buon. The unit rst appears in the
display and then the last set quanty.
Seng the metering quanty
Adjust the metering quanty using both keys (11) “+”
and “-”. The water quanty can be set in increments of
0.1 litres. Keep the buon depressed to advance quickly.