Care and maintenance
Clean equipment: Keep the instrument clean and remove any dirt immediately.
Clean the instrument with a damp cloth and a mild cleaning detergent (soap). Do not use
any cleaning agents containing solvents.
Changing the baeries: To change the baeries, open the baery compartment (3) cover using a screwdriver.
Remove the old baeries. Insert the new baeries (AA) in the baery compartment ac-
cording to the labelling. Remove the rubber seal from the cover and clean it. Do not dam-
age the seal. We recommend lubricang the seal with silicone grease.
Reinsert the rubber seal into the groove of the cover, ensuring the seal ts exactly.
Before screwing the cover back on, make sure that the rubber seal is not crushed. You can
tell that a seal is not properly seated as the gap in the cover is not parallel.
Place the cover so that it is level and screw it back into place with the 3 screws.
If the seals are not inserted correctly, this may impair the leak-ghtness of the instrument.
Do not reuse damaged seals.
Replacing the hose
connecon:
Loosen by turning counter-clockwise
Place the new hose coupling with seal on the thread and ghten in the clockwise direcon.
Cleaning the screen: There is a parculate screen in the water supply (5) that holds back larger parcles in the
supply water. It is recommended to clean the screen from me to me.
Unscrew the hose connecon as described above.
Use pliers to grab the screen at the protruding screen clip and pull it out.
Clean the screen under owing water and re-insert it.
Screw the hose connecon back on.
Back-ushing: There is also a screen before the water outlet (7). If the amount of water decreases signif-
icantly, this needs to be cleaned. The hose must be connected to the water outlet only for
this reason and this reason only. At the same me, the second screen at the water supply
(5) must be removed (see above). Then ush the instrument backwards to remove the
deposits. Then disconnect the hose and re-insert the screen at the water supply.
Water lter: The use of a pre-lter is recommended to supply the AQiX with water.
(mesh size 0.08 - 0.1 mm)
Nocaon in the display Descripon Reccaon
BAT nocaon in the display area
visualizes that the baery is empty
Change the baeries
Display of a circumferenal line
visualizes that there is no water in
the instrument
• Ensure a water supply to the instrument
• Check whether the instrument inlet is dirty
and remove any dirt if necessary
No nocaon in display aer
pressing the "START/PAUSE” buon
• Change the baeries
• If there is sll no nocaon aer changing
the baeries, then send in the instrument for
repair