(3) DC Battery Powering
Available for 14.8V-16.8V / 26V-28.8V
V-mount battery powering.
Attach the V-mount battery to the control
box, and connect the lamp body to the
control box via the cable.
Note: The MAX. load current for the battery
panel is 15A.
Note:
1)Please note that when powering CL600
employing a series-boost circuit scheme,
for the control box to work at full power,
it is required the input voltage to be >48V.
Thus:
① Powering by a 14.8V-16.8V V-Mount
battery: 16.8V * 15A = 252W. It is not
enough to illuminate the light(do not reach
half power).
② Powering by two 14.8V-16.8V batteries:
Maximum battery voltage is 33.6V and
meets half-power output requirements. It
will stop working when the battery voltage
drops to 20V.
③ Powering by a 26V-28.8V battery:
26V*15A = 390W, meeting half-power
output requirements. It will stop working
when the battery voltage drops to 20V.
④ Powering by two 26V-28.8V batteries:
52V*15A = 780W, meeting full-power
output requirements. It reduces power
when the battery voltage drops to 40V and stops working when voltage
drops to 20V.
2)Mixing 14.8V-16.8V / 26V-28.8V batteries is available.