Cleveland 24CGA6.2 handleiding
Handleiding
Je bekijkt pagina 7 van 30

3
CHAPTER 2 GENERAL OPERATION
A. MAIN EXTERNAL POWER SWITCH
Usually the steamers main power switch is left ON. If the
main external power switch was left in the OFF position,
turn it ON as follows.
1. Check that the water supply valves are open.
2. Turn the ON/OFF levers/switches counterclockwise to
the OFF position.
3. The TIMED/MANUAL switch and timer settings are
not important in this procedure. The control panel
circuits are not powered while the ON/OFF
levers/switch is set to OFF.
4. Refer to the main power switch in Figure 2-1, and turn
on electric power to the steamer. The steam
generators will immediately start blowdown cycles.
The blowdown cycle lasts 3 minutes.
B. DOOR INTERLOCK SWITCH
The steamer compartments of the Gemini Steamer are equipped with automatic steam cutoff switches,
which turn OFF the production of steam to a cooking compartment whenever the door to that compartment
is opened. NOTE: Even though the continued production of steam ends as soon as a door is opened, it may
take up to a minute for residual steam in the system to clear from the steam lines and the cooking
compartment. To avoid possible injury always wait until this residual steam has cleared before reaching into
the cooking compartment.
C. POWER ON (AUTOMATIC FILL)
When each steamer compartment is turned ON, it automatically fills its steam generator with water. Use this
procedure at the beginning of a shift to prepare the steamer for operation without starting steam generation.
When ready to start steam cooking, begin either the Timed or Manual Operating Procedure.
1. Press the TIMED (top) end of the TIMED/MANUAL switch (for ON/OFF models set the selector switch
to OFF..
2. Turn the ON/OFF lever/switch (see Figure 2-2 or 2-3), depending on model, clockwise to the ON
position to energize the steamer control panel. The red indicator light on the control panel lights, the
combustion blower turns ON to purge the generator and water fills the steam generator.
Figure 2-2 ON/OFF Leve
r
(Located below lower compartment)
Gemini
DRAIN LINE
COLD WATER SUPPLY LINES
MAIN POWER SWITCH
Figure 2-1 Main External Power Switch
Figure 2-3 ON/OFF Switch
(Located on control panel)
Bekijk gratis de handleiding van Cleveland 24CGA6.2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Cleveland |
Model | 24CGA6.2 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 3502 MB |