Trouble Shooting Guide
(Continued)
PROBLEM POSSIBLE CAUSE REMEDY/REFERENCE
Steam generator scale buildup Descale steam generator with Cleveland
Range approved descaler
Gas inlet pressure low See note #2
Reduced Steam flow into
cooking compartment
Inoperative or improperly adjusted
controls
See note #1
Water leaking from
bottom of cabinet
Broken or loose plumbing inside
steamer cabinet
Turn OFF electricity at main external
power switch and close water supply
valve(s) See note # 1
A small amount of water condensing
around the door is normal
No action necessary
External drain not properly installed,
should be free-air vented and
pitched down.
See notes #2 and #3.
External drain is blocked or
restricted
Clean external drain
See note #3
Door gasket or door parts worn See note # 1
Steam and / or water
draining around
compartment door
See Warning under
Note #7
Inoperative controls inside cabinet Turn OFF power at main external power
switch See note # 1
Water leaking from water
pipes or drain lines
Plumbing needs repair See note # 3
If steamer is new, or has just been
descaled
Press switch to reset descale timer
Steamer needs descaling Descale steamer with Cleveland Range
approved descaler After descaling is
completed, press switch to reset descale
timer
Descale Required
indicator is lit
Note: Switch does not
descale steamer, it is
just a reminder that
steamer must be
descaled every 4-6
weeks
Bad or improperly set descale timer See note #1
Timer fuse has blown (Electronic
timer models only)
See note #1ON/OFF Indicator ON but
steamer does not make
steam in timed mode
Inoperative timer control or damaged
wiring
See note #1
Water level floats are dirty and are
not moving properly or stuck
(21CGA5) or
Water probes are dirty (24CGA10)
Turn OFF water supply to steamer and
descale steamer manually with
Cleveland Range approved descaler
See Operators Manual for instructions
If condition persists see note #1
Water is flowing out of
steam ports into cooking
compartment
Inoperative controls or solenoid See note #1
Unit is equipped with mineral purge
cycle option
If only a small amount of water is coming
intermittently from drain. This is normal
operation see Chapter 2, Section I
Condenser valve is bad See note #1
Water coming from drain
even when not cooking
Drain solenoid is stuck partway open Turn OFF power to blowdown steamer. If
problem persists, see note #1.