3) Press TIMED end of TIMED/MANUAL switch (or for
ON/OFF Models put the ON/OFF selector Switch in
the OFF Position)
4) DO NOT start timer
• Water must be cold for descaling
• Open cooking compartment door(s)
• Leave cooking compartment door(s) open
5) Remove descaling port cap (see Figure 6-1)
6) Add required amount of Dissolve® through the
descale port while generator refills
• Pour slowly to avoid overflow
• Refill can take up to 8 minutes
• Use 1 gallon Dissolve® for Ultra 5 gas
• Use 1 ½ gallons Dissolve® for Ultra 10 gas
7) Add 1-2 gallons of cold tap water to descaling port after refill stops, continue to fill with cold
water until descaling solution enters cooking compartment(s) through steam nozzles
• Note: Some descaling solution will flow from drain of Ultra 10 gas steamers
• Adding extra water to generator(s) raises descaling solution to higher than normal
water fill level, allowing descaling solution to clean sensors and surfaces above
normal water fill level
8) Let descaling solution soak in generator(s) for 1 hour
9) After 1 hour, turn ON/OFF switch OFF to start 3 minute Automatic Blowdown
• This drains and rinses generator(s)
10) After Automatic Blowdown ends, turn ON/OFF switch to ON
11) Add cold tap water through descaling port after generator refills, until water enters cooking
compartment(s) through steam nozzles
• This raises the water level to rinse the surfaces cleaned in Step 8
12) Turn ON/OFF switch OFF to start 3 minute Automatic Blowdown to rinse generator
13) Replace descaling cap and close cooking compartment door(s)
14) Turn TIMED/MANUAL switch to TIMED
15) Turn steamer ON/OFF switch to ON and set TIMER for 20 minutes
• For Keypad Timer models: Press START/STOP key to begin the cook cycle
• For ON/OFF models: Turn the steamer ON for twenty minutes
16) After the timer counts down, turn ON/OFF switch to OFF to start Automatic Blowdown
17) After Automatic Blowdown cycle ends, reset DESCALE REQUIRED light
18) Descaling is complete, resume normal startup, cooking, and shutdown procedures