7
Model 21CGA5 Gas Fired Table Top Steam Generator and Cooker
Lighting Instructions – 21CGA5
1. Turn the ON/OFF SWITCH to the ON position
• Steam Generator will fill with water (about 5 minutes)
2. Turn ON the COOKING COMPARTMENT
• Spark will initiate and main gas valve will open for 4 seconds
• If the burner fails to light in 4 seconds then the gas valve will close and lock out
3. Turn ON the COOKING COMPARTMENT
4. System may be reset manually
• Wait 5 minutes
• Turn the ON/OFF SWITCH to OFF and back to ON
Shutdown Instructions – 21CGA5
1. Turn POWER ON/OFF Switch to OFF.
• Burners turn OFF
• Drain opens
• Steamer starts 3 minute blow down cycle
• Control panels de-energize
Model 21CGA10 Gas Fired Floor Mounted Steam Generator and Cooker
Lighting Instructions – 21CGA10
1. Turn the ON/OFF SWITCH to the ON position
• Steam Generator will fill with water (about 5 minutes)
2. Turn on a COOKING COMPARTMENT
• Blower will start and pilot will attempt to light for 90 seconds
• If no ignition occurs the system will automatically reset in 6-7 minutes
3. System may be reset manually
• Turn the ON/OFF SWITCH to OFF for 5 minutes
• Turn the ON/OFF Switch back ON
Shutdown Instructions – 21CGA10
1. Turn POWER ON/OFF CONTROL to OFF.
• Burners turn OFF
• Drain opens
• Steamer starts 3 minute blow down cycle
• Control panels de-energize
DANGER
Steam leaks around the door, cooking compartment flooding,
reduced cooking performance, and compartment implosion
can be caused by a blocked drain or drain screen.
Inspect and clean the drain and drain screen before each use.