D. GENERATOR VENT – IMPORTANT
IMPORTANT
When installing this steamer, under no
circumstances should the Steam Vent (See
Figure 1-2), be removed, capped or attached to
piping of any kind.
This fitting is an auxiliary safety intended to
prevent any pressure from building up in the
generator in the unlikely event the steam outlets
of the steamer should become plugged or
restricted.
CHAPTER 2 INSTALLATION INSTRUCTIONS
A. GENERAL
This equipment should only be installed by qualified, professional plumbers, pipe fitters, and electricians.
•
The steamer is to be installed to comply will the applicable Federal, State or Local Plumbing Codes,
with the National Fuel Gas Code, ANSI Z223.1-(latest edition) or the Natural Gas Installation Code
CAN/CGA-B149.1 or the Propane Installation Code CAN/CGA-B149.2 as applicable, The National
Electrical Code, ANSI/NFPA No. 70-(latest edition) or the Canadian Electrical Code, CSA C22.2 as
applicable, the Food Service Sanitation Manual of the Food and Drug Administration (FDA) and all
applicable state and local codes and regulations.
•
The installation instructions must be read in their entirety before starting the installation of this steamer.
•
To install this steamer, the following requirements must be considered when selecting a location.
a. A suitable drain must be available within 12 ft. of the steamer. Do NOT install the appliance directly
over a drain. Steam rising up out of the drain will adversely affect operation, hamper cooling air
circulation, and damage electrical and electronic components. NOTE: The drain MUST NOT be
located beneath the steamer itself.
b. An electrical supply matching the power requirements found on the rating plate must be available,
which is not of the GFCI (Ground Fault Interrupter Circuit) type.
c. A gas supply matching the fuel requirements found on the rating plate must be available.
d. The location must have sufficient space to meet the clearance requirements of the steamer as
outlined in Chapter 2, Section B, Part 1, “Locating the Steamer”.
e. A water supply meeting the requirements outlined in Chapter 2, Section B, Part 6 “Water Supply
Requirements and Installation” must be available.
WARNING
DEATH, INJURY, AND EQUIPMENT DAMAGE could result from the
improper installation, adjustment, alteration, service or maintenance of
a steamer or installation of a unit damaged during shipment or storage.
Any of these conditions could also void the equipment warranty.
DO NOT INSTALL a Gemini steamer that has been damaged.
Install the Gemini steamer according to the policies and procedures
outlined in this manual.
Figure 1-2 Generator Vent