Cleveland 24CGA10.2ES handleiding
Handleiding
Je bekijkt pagina 30 van 57

2. Blowdown Frequency
The supply water quality determines how often blowdown must be performed. The more the steamer is
used and the higher the content of total dissolved solids and particulates in the feed water, the more
frequently blowdown must be performed. A determination should be made at the time of installation
whether additional blowdown frequency will be required as part of the daily maintenance based on the
water quality analysis done as part of the installation. This information should be noted in the daily
maintenance program developed for the equipment. After it has been determined whether the local
water supply meets the minimum supply water quality standards, observe the following guidelines to
establish proper blowdown scheduling.
•
When using a supply water system that does not meet the minimum supply water quality standards,
blowdown must be performed after every 4 hours of operation and at the end of each shift.
•
For units using water that meets the minimum supply water quality standard, whether naturally or by
using a water treatment system, blowdown must be performed at the end of each shift.
3. Blowdown Procedure
When each steamer is turned OFF, its blowdown cycle starts and runs automatically. The complete
cycle takes approximately 3 minutes.
(1) Turn the ON/OFF lever/switch to the OFF position to turn OFF the steamer. The red indicator light
turns OFF and the drain valve is opened. Do not turn power OFF at the main external power switch
during blowdown.
(2) The drain valve begins to draw water from the steam generator.
(3) The fill valve operates for 3 minutes to help flush any debris through the drain valve as the
generator drains.
(4) At the end of the 3-minute blowdown cycle, the fill valve closes.
(5) When blowdown is complete, the steamer can be restarted, or the shut down procedure completed.
•
To restart the unit, refer to POWER ON (AUTOMATIC FILL) in Chapter 2, Part C.
•
To shut down the unit, refer to SHUT DOWN AND CLEANING, below.
NOTE: The ON/OFF lever/switch must be turned fully to the OFF position to properly START the
automatic blowdown of the steamer.
B. SHUT DOWN AND CLEANING
This procedure should be performed at the end of each day or shift.
1. Refer to Power OFF (Automatic Blowdown), and turn off the steamer compartment. Allow 3 minutes for
the complete blowdown cycle.
WARNING
Do not use a hose or water jet to clean this appliance
WARNING
SEVERE BURNS may result from exposure to steam.
Do not open the steamer door before steam flow stops. Stand back when opening
the compartment door. Open the door slightly to allow steam to vent before looking
or reaching into cooking compartment. Do not reach into cooking compartment until
the steam has cleared.
Do not reach into steamer or handle hot items without wearing heatproof gloves. Wet
or damp gloves conduct heat, and may cause burns when touching hot items.
Bekijk gratis de handleiding van Cleveland 24CGA10.2ES, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Cleveland |
Model | 24CGA10.2ES |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 14871 MB |