Table 2-1. Minimum Water Quality Requirements
Scale Forming Factors
Total Dissolved Solids less than 60 parts per million
Silica less than 13 parts per million
Alkalinity less than 20 parts per million
Corrosion-Causing Factors:
Free Chlorine less than 0.5 parts per million
Chloride less than 30 parts per million
PH factor greater than 7.5
2). Water Supply System
Provide a water supply system that fulfills the requirements of the limits listed in Table 2-1. The
supply must provide a minimum dynamic pressure of 35 psi (2.4 kg/cm
2
) and a maximum static
pressure of 60 psi (4.1 kg/cm
2
).
If analysis shows that the supply water is NOT within the required limits, either a water
treatment system and/or carbon filter must be installed in the line feeding the steam
generator or the frequency of maintenance, cleaning, and descaling must be increased
beyond that recommended in the maintenance schedule (Chapter 3). If more frequent
descaling is selected as the means of protecting the steamer from premature failure, the
“DESCALE REQUIRED” light timing should be readjusted to reflect the increased cleaning
schedule.
b. Setting the Descale Required Light
The Descale Required Light feature tracks
the number of hours the unit has been
operating since it was last reset, and lights
when it is time for descaling.
1). General
The Descale Required Light consists of an
indicator light, a solid state timer module,
and a reset/rocker switch. (The light and
reset switch consist of a single device on
the front panel identified by the
“DESCALE REQUIRED” label.) See
Figure 2-11. The timer is a digital clock
module inside the unit that keeps track of
how many hours your steamer has been
in operation since the last reset of the
timer.
DESCALE REQUIRED LIGHT/RESET
SWITCH.
Figure 2-11 Descale Required Light
and Timer Module