is drained. Blowdown at frequent intervals helps decrease mineral buildup in the steam generators, and
reduces the frequency of descaling and other maintenance.
2. Blowdown Frequency
The supply water quality determines how often blowdown must be performed. The more the steamer is
used and the higher the content of total dissolved solids and particulates in the feed water, the more
frequently blowdown must be performed. A determination should be made at the time of installation
whether additional blowdown frequency will be required as part of the daily maintenance based on the
water quality analysis done as part of the installation. This information should be noted in the daily
maintenance program developed for the equipment. After it has been determined whether the local
water supply meets the minimum supply water quality standards, observe the following guidelines to
establish proper blowdown scheduling.
·
When using a supply water system that does not meet the minimum supply water quality standards,
blowdown must be performed after every 4 hours of operation and at the end of each shift.
·
For units using water that meets the minimum supply water quality standard, whether naturally or by
using a water treatment system, blowdown must be performed at the end of each shift.
3. Blowdown Procedure
When each steamer is turned OFF, its blowdown cycle starts and runs automatically. The complete
cycle takes approximately 3 minutes.
(1) Turn the ON/OFF lever/switch counterclockwise to the OFF position to turn OFF the steamer. The
red indicator light turns OFF and the drain valve is opened. Do not turn power OFF at the main
external power switch during blowdown.
(2) The drain valve begins to draw water from the steam generator.
(3) The fill valve operates for 3 minutes to help flush any debris through the drain valve as the
generator drains.
(4) At the end of the 3-minute blowdown cycle, the fill valve closes.
(5) When blowdown is complete, the steamer can be restarted, or the shut down procedure completed.
·
To restart the unit, refer to POWER ON (AUTOMATIC FILL) in Chapter 2,Part C.
·
To shut down the unit, refer to SHUT DOWN AND CLEANING, below.
NOTE: The ON/OFF lever/switch must be turned fully to the OFF position to properly START the
automatic blowdown of the steamer.
B. SHUT DOWN AND CLEANING
This procedure should be performed at the end of each day or shift.
1. Refer to Power OFF (Automatic Blowdown), and turn off the steamer compartment. Allow 3 minutes for
the complete blowdown cycle.
WARNING
Do not use a hose or water jet to clean this appliance.