27
Trouble Shooting Guide
(Continued)
PROBLEM POSSIBLE CAUSE REMEDY/REFERENCE
Operating in manual mode. Switch to timed mode for timer to control
steam flow.
Steam flow does not stop
when TIMER stops.
Inoperative controls inside cabinet. Turn OFF power to that compartment at
ON/OFF lever/switch. See note #1.
Pans too close to bottom of cabinet Put pans in racks near top of cabinet
Compartment overloaded with too
much food
Put less food into pan
Use fewer pans
Food is being cooked in covered
solid pans
Remove covering
Steam must have direct access to food
for cooking to take place
Food is frozen Increase cooking times for frozen food
Suggested cooking times are usually
listed for cooking at sea level
Extend cooking times for altitudes above
2000 feet
Hot water connected to condenser
line
Make proper connections See section on
Water Supply. See note # 3
Condenser water is turned OFF Turn ON water to condenser
Condenser water line strainer and/or
nozzle is clogged
Clean out condenser water supply
strainer and/or nozzle
Steam generator scale buildup Descale steam generator with Cleveland
Range approved descaler
Food takes too long to
cook
To verify steamer’s
proper operation see
note #6
Inoperative or improperly adjusted
controls
See note #1
Descale cap is missing Install descale cap. Descale port must
be closed tightly for steamer to operate
properly. If missing see note #8
Descale cap is loose Tighten descale cap. Descale port must
be closed tightly for steamer to operate
properly
Water comes out of
descale port
Descale cap and/or gasket is
damaged
See note #8
TROUBLESHOOTING NOTES
1. If problem is inside the steamer, call a qualified Cleveland Range authorized service representative.
Cleveland Range will not pay for warranty repairs by unauthorized repair centers.
2. Proper installation of the steamer is the responsibility of the owner or installer. Call a qualified Cleveland
Range authorized service representative to correct the installation. Refer to Cleveland Range Warranty.
3. Repairs to external plumbing should be done by a Licensed Plumber.
4. Repairs to external wiring should be done by a Licensed Electrician.
5. For more information on products and services, contact your nearest Authorized Sales Representative.
Call factory for preventative maintenance programs, descaling kits, descaling information, and water
treatment systems: USA: (800) 338-2204, Canada: (800) 427-6668.
6. To evaluate whether a SteamCraft
®
steamer is producing normal cooking performance, conduct the
Egg Test as follows (NOTE: this test is not valid for pressure steamers). A properly operating steamer
will produce cooked eggs as follows.