Cleveland 21CGA5 handleiding
Handleiding
Je bekijkt pagina 31 van 40

25
B. TROUBLESHOOTING GUIDE
The Troubleshooting Guide is a list of symptoms that may occur during routine operation.
• “Problem” (left column) lists common operating problems.
• “Possible Cause” (center column) lists causes of problems in order they should be checked.
• “Remedy / Reference” (right column) lists fixes for problems from easiest to hardest.
• “Notes” in “Remedy / Reference column are at end of Table 6-1 Troubleshooting Guide.
ATTEMPTING TO REPAIR OR CORRECT PROBLEMS REQUIRING A QUALIFIED CLEVELAND
RANGE AUTHORIZED SERVICE REPRESENTATIVE VOIDS WARRANTY
Trouble Shooting Guide
Table 6-1
PROBLEM POSSIBLE CAUSE REMEDY/REFERENCE
Power turned OFF at main external
power switch or breaker
Turn ON power at main external power
switch or breaker
Power indicator light
does not turn ON when
ON/OFF switch is in the
ON position
Inoperative controls or failed light See note #1
Water supply to steamer shut off Open water supply valves
Water line strainer and/or external
filter system is clogged
Clean water supply strainer and/or filter
system
Power ON but steam
generator does not fill
Inoperative solenoids or controls See note # 1
Water supply to steamer shut OFF Open water supply valves
Door interlock switch not engaged or
has failed (if unit has this option)
Close door completely If problem
persists, see note #1
Water line strainer and/or external
filter is clogged
Clean water supply strainer and/or
external filter system
Gas supply valve is closed Open gas supply valve
Control panel POWER
indicator light ON and
steamer does not make
steam in MANUAL or
TIMED modes
Inoperative controls or solenoid See note # 1
Hot water instead of cold water
connected to condenser fitting
Make proper connections See section
on Water Supply
Water supply to condenser turned
OFF
Open water supply valve
Condenser water line strainer and/or
nozzle clogged
Clean out condenser water supply
strainer and/or nozzle
Water supply line to condenser
blocked, broken, or leaking
Repair or replace water supply line See
note # 1
Abnormal amount of
steam coming from drain
Inoperative controls, thermostat or
solenoids
Turn OFF electricity at main external
power switch See note # 1
Timer transformer has failed See note #1Power light is ON, but
timer does not light
(Electronic Timer models
only)
Inoperative controls See note #1
Compartment bottom
dirty with food drippings
Juices and/or food leaking from pans Put a solid pan under perforated pans to
catch drippings, or put less food in pans
(Continued On Next Page)