8 Troubleshooting
9 Cleaning instructions
The window must be clean. If the window is dirty, the barcode may not be read.
Clean it regularly—or immediately, if it becomes dirty—using a damp cloth and a conventional window
cleaner.
Do not use acidic cleaners or acetone. These can dissolve the plastic.
Remove suspension bail.
Problem Possible cause Measure
Accessory does not work Accessory not activated by software See Troubleshooting
Accessory not properly installed Check installation
Accessory defective Replace accessory
Tool defective Replace tool
Wrong software on TIM Perform software update with
correct software
Wrong software on STMD-H Perform software update with
correct software
TIM defective Send tool for repair
Application is not
loaded
Measurement card software is not
recognized
Use correct measurement card
software
No application on the tool Perform software update with
correct software
CAN bus communication not
possible
Make sure the tool is installed
correctly
Make sure the correct TIM soft-
ware is used
Barcode is not read Barcode damaged Use another barcode
Wrong barcode type used Use another barcode type
Wrong barcode type parameterized Enable barcode type on the
controller