ClearOne Converge Pro 840T handleiding

366 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 119 van 366
114
Pre Gain Meter
The Pre Gain meter displays the mic input level before gain adjustments. Meter range is determined by the Coarse
Gain Slider in the Gain section of the screen as described below.
NOTE: All meters in Console are peak-level meters.
Gain Section
The Coarse and Fine gain sliders are used to match the level settings between mic inputs, and to adjust the
volume level for a given mic input channel. The Min/Max fine gain sliders are used to set minimum and maximum
gain settings, and to report min/max gain settings via serial commands.
In general, you should set the Coarse gain slider to 56dB for a mic input, 28dB for active equipment that requires
an input between mic and line level, or 0dB for a line level input device.
Use the Fine gain slider to adjust input volume level. You can also set fine gain in .5dB increments using the Up/
Down buttons, or enter a value directly in the field.
Post Gain Meter
The Post Gain Meter displays the audio level after gain adjustments.
Post Process Meter
The Post Process Meter displays the audio level after it passes through all mic input processing, such as Processing
channels, Filters, AEC, NC, AGC/ALC, and Mute.

Bekijk gratis de handleiding van ClearOne Converge Pro 840T, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkClearOne
ModelConverge Pro 840T
CategorieNiet gecategoriseerd
TaalNederlands
Grootte58248 MB

Caratteristiche Prodotto

Gewicht3.3375 g
Aantal Ethernet LAN (RJ-45)-poorten2
RS-232 port1
Ingangsspanning100 - 240 V
Frequentie50/60 Hz