Cigweld Transmig 4RT handleiding
Handleiding
Je bekijkt pagina 50 van 62

TRANSMIG 4RT BASIC WELDING
BASIC WELDING 4-6 Manual 0-5245
Basic MIG (GMAW/FCAW) Welding Troubleshooting
FAULT CAUSE REMEDY
1 Undercut A Welding arc voltage too high. A Decrease voltage or increase the wire feed speed.
B Incorrect MIG Torch angle B Adjust angle.
C Excessive heat input C Increase the MIG Torch travel speed and/or decrease welding
current by decreasing the voltage or decreasing the wire feed
speed.
2 Lack of penetration A Welding current too low A Increase welding current by increasing wire feed speed and
increasing voltage.
B Joint preparation too narrow or
gap too tight
B Increase joint angle or gap.
C Shielding gas incorrect C Change to a gas which gives higher penetration.
3 Lack of fusion Voltage too low Increase voltage.
4 Excessive spatter A Voltage too high A Decrease voltage or increase the wirespeed control.
B Voltage too low B Increase the voltage or decrease wirespeed.
5 Irregular weld shape A Incorrect voltage and current
settings. Convex, voltage too low.
Concave, voltage too high.
A Adjust voltage and current by adjusting the voltage control and
the wirespeed control.
B Wire is wandering. B Replace contact tip.
C Incorrect shielding gas C Check shielding gas.
D Insufficient or excessive heat
input
D Adjust the wirespeed control or the voltage control.
6 Weld cracking A Weld beads too small A Decrease travel speed
B Weld penetration narrow and
deep
B Reduce current and voltage and increase MIG Torch travel speed
or select a lower penetration shielding gas.
C Excessive weld stresses C Increase weld metal strength or revise design
D Excessive voltage D Decrease voltage.
E Cooling rate too fast E Slow the cooling rate by preheating part to be welded or cool
slowly.
7 Cold weld puddle A Loose welding cable connection. A Check all welding cable connections.
B Low primary voltage B Contact supply authority.
C Fault in power source C Have an Accredited CIGWELD Service Provider test then replace
the faulty component.
8 Arc does not have a crisp
sound that short arc
exhibits when the wirefeed
speed and voltage are
adjusted correctly.
The Wirefeeder has been
connected to the wrong voltage
polarity on the front panel of the
power source.
Connect the Wirefeeder to the positive (+) welding terminal
for solid wires and gas shielded flux cored wires. Refer to the
electrode wire manufacturer for the correct polarity.
Table4-3: GMAW (MIG) Welding Problems
Bekijk gratis de handleiding van Cigweld Transmig 4RT, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Cigweld |
| Model | Transmig 4RT |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 8070 MB |