ERROR CODE CAUSE REMEDY
Wirefeed
Motor
Overload
A
MIG wire jammed in conduit liner or
contact tip. (burn-back jam). Check
for clogged / kinked MIG torch
conduit liner or worn contact tip.
Replace faulty components.
B
Check Feed Roll Pressure
adjustment and adjust if necessary.
Refer to Section 5.08.
C
Check Wire Reel Brake setting and
adjust if necessary. Refer to Section
5.06.
D
If Error Code is still present on
the Display contact an Accredited
Cigweld Service Provider.
Loss of
Supply
Phase
A
Check the Power Source Supply Plug
is correctly connected to the Supply
Socket.
B
Check the Power Source Supply
Lead is not damaged. If damaged
turn off the supply and contact an
Accredited Cigweld Service Provider.
C
If Error Code is still present on
the Display contact an Accredited
Cigweld Service Provider.
66 | CIGWELD.COM.AU