6.06 BLUEVENOM 4R-ROVER ERROR CODES
ERROR CODE CAUSE REMEDY
Over
temperature
A
Duty cycle of the Power Source has
been exceeded. Leave the power
source switched ON with the fan
running and allow it to cool.
B
Check the Power Source front and
rear Panel Air Louvers are clean and
not blocked by any dirt or obstacles.
If damaged they should be replaced
by an Accredited Cigweld Service
Provider.
C
Check that the Power Source fan
is running normally during welding.
If the Power Source fan is not
running during welding it may be
faulty and need replacing. Contact
an Accredited CIGWELD Service
Provider. Note the BlueVenom 4
Wheeled Power Source has Fan
on Demand tted. Refer to Power
Source Operating Manual for details.
MIG gun
Trigger
Signal Issue
A
Check that the Torch Trigger Switch
is not pressed.
B
MIG Gun Trigger leads or switch
shorted. Turn Off the Power Source
and repair or replace Torch lead or
switch.
C
If Error Code is still present on
the Display contact an accredited
Cigweld Service Provider.
Output Over
Current
A
Set the output current according
to the Power Source Rating Label
located on the Rear Panel of Power
Source.
B
If Error Code is still present on
the Display contact an accredited
CIGWELD Service Provider.
Output Short
Circuit
A
Check that MIG Wire is not short
circuited to the workpiece.
B
If Error Code is still present on
the Display contact an Accredited
Cigweld Service Provider.