CRATER FILL TIME (CFT)
Crater Fill Time is the time in seconds that the Crater Fill
parameters ramp down to achieve Crater Fill nish at the end
of the weld.
Crater Fill Time operates when Crater Fill (CRF) is ON (refer
above).
Press the Menu Button then the Forward and Back Menu Arrow
Buttons to cycle through the Advanced Settings until reaching
Crater Fill Time (CFT). Once selected use the Right Control Knob
to set the desired value. This parameter has an adjustment
range of 0.1 – 9.9 seconds.
Factory setting for Crater Fill Time is 0.5 seconds.
Once set exit Advanced Settings by pressing the Menu Button
and the Menu indicator will turn off.
CRATER FILL WIRE FEED SPEED (CFW)
Crater Fill Wire Feed Speed is used to set the nish wire feed
speed for MIG.
Press the Menu Button then the Forward and Back Menu Arrow
Buttons to cycle through the Advanced Settings until reaching
Crater Fill Wire Feed Speed (CFW). Once selected use the Right
Control Knob to set the desired value. This parameter has
an adjustment range of 2.0 – 18.0 metres per minute (M/Min).
Factory setting for Crater Fill Wire Feed Speed is 2.5 metres
per minute (M/Min).
Once set exit Advanced Settings by pressing the Menu Button
and the Menu indicator will turn off.
CRATER FILL VOLTAGE (CFU)
Crater Fill Voltage is used to set the nish voltage for MIG.
Press the Menu Button then the Forward and Back Menu
Arrow Buttons to cycle through the Advanced Settings until
reaching Crater Fill Voltage (CFU). Once selected use the Right
Control Knob to set the desired value. This parameter has an
adjustment range of 13.0 – 40.0 Volts. Factory setting for Crater
Fill Voltage is 14.0 Volts.
Once set exit Advanced Settings by pressing the Menu Button
and the Menu indicator will turn off.
RUN IN (RIN)
Press the Menu Button then the Forward and Back Menu Arrow
Buttons to cycle through the Advanced Settings until reaching
Run In (RIN). Once selected use the Right Control Knob to set
the desired value. This parameter is adjusted as a Percentage
% of the Set Wire Feed Speed. Adjustment Range is 1 – 100%.
Factory setting for Run In is 100%.Once set exit Advanced
Settings by pressing the Menu Button and the Menu indicator
will turn off.
The user can set the MIG wire Run In speed before the Arc
is initiated. Once the Arc is initiated the MIG Wire Speed will
revert to the user set Wire Feed Speed (WFS) setting.
SPOT WELDING MODE (SPT)
Spot welding is used to weld two thin plates together at a
desired location by melting the top and bottom plates together
to form a nugget between them.
Operates in Trigger 2T mode only.
Press the Menu Button then the Forward and Back Menu
Arrow Buttons to cycle through the Advanced Settings until
reaching Spot Welding Mode (SPT). Once selected use the Right
Control Knob to set the desired value. This parameter has an
adjustment range of 0 – 5.0 seconds. Factory setting for Spot
Time is 0 seconds.
Once set exit Advanced Settings by pressing the Menu Button
and the Menu indicator will turn off.
OPERATING MANUAL BLUEVENOM 4R-ROVER
CIGWELD.COM.AU | 53