H
RIGHT CONTROL KNOB
PRESS TO STEP THROUGH SELECTIONS AND SELECT OPTIONS
IN MIG QUICKSET MODE
Inductance, Shielding Gas, Trigger Mode (2T/4T),
and Volts Trim.
I
INDUCTANCE
The Inductance (arc) control operates in MIG (GMAW) modes
only and is used to adjust the intensity of the welding arc.
Lower arc control settings make the arc softer with less weld
spatter. Higher arc control settings give a stronger driving arc
which can increase weld penetration.This parameter has an
adjustment range of -10 to 10.
Factory setting for Inductance is 0.
J
SHIELDING GAS (GAS)
SELECT SHIELDING GAS TYPE OR GASLESS MODE
Select the correct Shielding Gas Type depending on the MIG
Wire Diameter and Material Type selected or (NO-GAS) for
Gasless mode. If in doubt, consult the MIG wire manufacturer.
K
TRIGGER MODE
SELECT TRIGGER MODE BUTTON
The trigger mode control is used to switch the functionality of
the MIG Gun trigger between 2T (normal) and 4T (latch mode).
2T NORMAL MODE
In this mode, the MIG Gun trigger must remain depressed for
the welding output to be active. Press and hold the MIG Gun
trigger to activate the power source (weld). Release the MIG
Gun trigger switch to cease welding.
4T LATCH MODE
This mode of welding is mainly used for long welding runs to
reduce operator fatigue. In this mode the operator can press
and release the MIG Gun trigger and the output will remain
active. To deactivate the power source, the MIG Gun trigger
switch must again be depressed and released, thus eliminating
the need for the operator to hold the MIG Gun trigger.
L
VOLTS TRIM
Volts Trim format is not available in MIG Manual Mode. The LED
Display will show Syn for QuickSet value for the selected Wire
and Plate Thickness. Volts Trim has a range of -5.0 to +5.0
Volts. If the value has been changed, to return to the factory
parameters simply return the Volts Trim to display Syn to
return to the QuickSet Voltage Value.
For example, if the Pre-set Voltage is 20V and in volts trim V+/-
mode the setting is changed to -2.0 then the Pre-set voltage
will now be 18V. If the Volts Trim V+/- is changed to 3.0 then
the Pre-set Voltage will be 23V.
M
MENU BUTTON
PRESS THE MENU BUTTON TO ACCESS ADVANCED SETTINGS
PRE GAS (PEG)
Shielding Gas ows for the time specied before an arc is
initiated.
Press the Menu Button then the Forward and Back Menu Arrow
Buttons to cycle through the Advanced Settings until reaching
Pre Gas (PEG). Once selected use the Right Control Knob to set
the desired value. This parameter has an adjustment range of
0 - 20 seconds.
Factory setting for Pre Gas is 0 seconds.
Once set exit Advanced Settings by pressing the Menu Button
and the Menu indicator will turn off.
POST GAS (PTG)
Shielding Gas ows for the time specied after an arc has
extinguished.
Press the Menu Button then the Forward and Back Menu Arrow
Buttons to cycle through the Advanced Settings until reaching
Post Gas (PTG). Once selected use the Right Control Knob to set
the desired value. This parameter has an adjustment range of
0 - 20 seconds.
Factory setting for Post Gas is 0.5 seconds.
Once set exit Advanced Settings by pressing the Menu Button
and the Menu indicator will turn off.
BURNBACK (BBT)
The Burnback Control is used to adjust the amount of MIG wire
that protrudes from the MIG Gun after the completion of MIG
welding (commonly referred to as stick out).
Press the Menu Button then the Forward and Back Menu Arrow
Buttons to cycle through the Advanced Settings until reaching
Burnback (BBT). Once selected use the Right Control Knob to
set the desired value. This parameter has an adjustment range
of 0.01 – 0.5 seconds.
Factory setting for Burnback is 0.01 seconds.
Once set exit Advanced Settings by pressing the Menu Button
and the Menu indicator will turn off.