5.13 SETUP WITH SPOOL GUN FOR GASLESS MIG WIRE
A. Connect the Euro MIG Spool Gun / Push-pull Gun to the front of the 4R-Rover Wirefeeder as you would to the front of the
BlueVenom Wheeled Power Source. Refer also to Section 5.02.
Connect the Spool Gun 8 pin Control Plug to the 8 pin Remote Control Socket on the Front Panel of the Remote Feeder. Ensure 8
pin plug is correctly tted to the 8 pin socket and the collar on plug is tightened rmly.
B. The 4R-Rover Wirefeeder is supplied with an 8 metre Interconnection Lead assembly to connect from the rear of the 4R-Rover
Wirefeeder to the front of the BlueVenom Wheeled Power Source.
C. Connect the Interconnection Lead Welding Power Cable from the Male “Welding Power“ Terminal located on the Rear Panel of
the 4R-Rover to the negative (-) terminal on the front of the BlueVenom Wheeled Power Source.
Check with wire manufacturer for recommended polarity.
D. Connect the Interconnection Lead Control Cable with 10 Pin Plug from the “Remote” 10 Pin socket on the rear of the 4R-Rover to
the Wirefeeder to the 10 Pin Socket on the front of the BlueVenom Wheeled Power Source.
E. Fit the correct V Knurled Feed Rolls for the Gasless MIG wire being used. Refer to section 2.10 Options and Accessories for Feed
Roll types and Part Numbers.
F. Switch the BlueVenom Wheeled Power Source On/Off switch located on the rear of the Power Source to the On position and
ensure the Power indicator on the Front Display is illuminated.
G. On the BlueVenom Wheeled Power Source press the Device Selection Button to select Remote Feeder.
C
Refer to the BlueVenom Wheeled Power Source Operating Manual for further details.
H. On the 4R-Rover select the Gasless MIG Mode for the application. Refer to Section 4.02 (B).
I. Feed wire through the wire drive mechanism. Refer to section 5.07.
J. Connect the work lead to the positive welding terminal (+). If in doubt, consult the wire manufacturer. Welding current ows
from the Power Source via DINSE terminals. It is essential, that the male plug is inserted and turned securely to achieve a
sound electrical connection.