Chef CFG517 handleiding

36 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 36
Chef 540 Upright Cooker 9
Installation
Checking pipe size
To work out a suitable pipe size for connection use the
information in this table.
Gas Consumption (MJ/h)
Model Natural gas Universal LPG Propane
CFG501
58.1 45.7 56.5
CFG504 47 36.7 47.5
CFG505 47 36.7 47.5
CFG513 60.2 48.2 58.3
CFG517 49.1 39.2 49.3
Wiring connection for gas cooker
To allow for disconnection of the appliance after installation,
the plug must be accessible after installation, or a functional switch
must be provided near the appliance in an accessible position.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
Gas connection
Read these points before connecting to the gas supply:
The cooker inlet connection point has a ½” BSP
externalthread. See Diagram below
A gas regulator is supplied
It is recommended to fit the regulator to the
applianceconnection point, then fit either hard piping or a
high levelflexible connection (AS/NZS 5601.1) which is
then attached
to the consumer hard piping
Ensure installation allows withdrawal of appliance.
Restraining Device
Anchor Points
Gas
Connection Point
150mm
650mm
Restraining Device
Anchor Points
Gas
Connection Point
CFG503 58.1 45.7 56.5

Bekijk gratis de handleiding van Chef CFG517, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkChef
ModelCFG517
CategorieFornuis
TaalNederlands
Grootte6753 MB