12. Can the spray tip on the wand be replaced with a different type of tip?
Yes, however your wand comes with a #18 tip which is standard. Brass tips generally
produce better spray patterns than plastic.
13. Each time I turn on the pump my fuse blows.
• Excessive voltage
• Improper adjustment of the pressure switch
• Damaged wiring harness.
14. Pump continues to run and surge when not spraying.
Ensure your system has no leaks. Check by-pass valve to ensure it’s not letting too
much fluid to bypass. If too much fluid is bypassed, the system is unable to build
enough pressure to shut-off.
Chapin Spot Sprayer Operators Manual - English
Due to our ongoing product improvement process, product specifications may change without notice. U.S. and foreign patents pending.
Congratulations!
You have just purchased a quality Chapin product.
Register Your Spreader Online@ www.chapinmfg.com/warranty.asp
DIAPHRAGM PUMP SPECIFICATIONS
Fits Chapin 15 and 25 gallon ATV sprayers
12 Volt DC, totally enclosed, non ventilated
Max amp rating: 10
Leads: 6” long
2.5 GPM, 12-volt Diaphragm Pump with quick connect alligator clips
Priming Capabilities: 4 feet [1.2 ml)
Max Pressure: 60 PSI
Inlet/Outlet Ports: Ouick Attach
[2] 3/4” to 3/8” Straight
[1] 3/4” to 3/8” 90