Chapin 97301 handleiding
Handleiding
Je bekijkt pagina 10 van 32

12. Can the spray tip on the wand be replaced with a different type of tip?
Yes, however your wand comes with a #18 tip which is standard. Brass tips generally
produce better spray patterns than plastic.
13. Each time I turn on the pump my fuse blows.
• Excessive voltage
• Improper adjustment of the pressure switch
• Damaged wiring harness.
14. Pump continues to run and surge when not spraying.
Ensure your system has no leaks. Check by-pass valve to ensure it’s not letting too
much fluid to bypass. If too much fluid is bypassed, the system is unable to build
enough pressure to shut-off.
Chapin Spot Sprayer Operator’s Manual - English
Due to our ongoing product improvement process, product specifications may change without notice. U.S. and foreign patents pending.
Congratulations!
You have just purchased a quality Chapin product.
Register Your Spreader Online@ www.chapinmfg.com/warranty.asp
DIAPHRAGM PUMP SPECIFICATIONS
Fits Chapin 15 and 25 gallon ATV sprayers
12 Volt DC, totally enclosed, non ventilated
Max amp rating: 10
Leads: 6” long
2.5 GPM, 12-volt Diaphragm Pump with quick connect alligator clips
Priming Capabilities: 4 feet [1.2 ml)
Max Pressure: 60 PSI
Inlet/Outlet Ports: Ouick Attach
[2] 3/4” to 3/8” Straight
[1] 3/4” to 3/8” 90’
SPRAY & PUMP FAQ, continued
Bekijk gratis de handleiding van Chapin 97301, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Chapin |
Model | 97301 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 4326 MB |