ChamSys SnakeSys B4 handleiding

61 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 21 van 61
SnakeSys User Manual 14 / 54
3.11 Rear Panel Diagram
The two NET ports on the back of the device do not have PoE (Power over Ethernet) functionality. Both ports can be of general
use, and NET4 can also be used as the VPN link between two R4 units.
3.12 ChamNet Mode Information
In ChamNet Mode, the SnakeSys R4 is configured and controlled from the Net Manager within MagicQ.
Note
The R4 unit will remember the settings that you make in MagicQ Net Manager. If the unit is left in MagicQ ChamNet mode it will
boot up with the settings that you made previously in Net Manager. (MagicQ will not be required to be connected via network
to retain the settings).
3.13 Powering the SnakeSys R4
SnakeSys R4 is powered using the supplied Powercon cable.
The power supply is universal wide range input type and has the following specification: 85 to 264VAC @ 47 to 63Hz
Caution
During usage please ensure that the unit has adequate ventilation and that the cooling grilles on the unit are not
obstructed.
3.13.1 Thermal Management
The SnakeSys R4 contains its own thermal management system. The fan is automatically controlled for regulation of the internal
temperature of the unit.