SnakeSys User Manual 9 / 54
2.11 Factory reset
From V215 firmware, it is possible to reset the IP address of the B4 if it has been changed via ChamNet.
To clear settings, disconnect the power and set all DIP switches to the OFF position and set both address switches to F. Then
power on the unit.
Unit will toggle both the NET and MQ LED’s if the settings were not already set as default and the default settings were restored.
Unit will flash both the NET and MQ LED’s together if the settings are already set as default and flash erase is not required.
Note that from V215 address FF is no longer a valid ChamNet address.
All internal settings are reset including port configuration.