Installation
STANDARD HOT WATER CONNECTION
CAUTION: To prevent damage to the dishwasher supply valves, the installing
plumber must thoroughly flush debris from the water supply line before
connecting it to the dishwasher. Damage caused by improper installation is not
covered by the limited warranty.
HOT
WATER
BOOSTER
RISE °F
MINIMUM INCOMING
WATER TEMPERATURE
MINIMUM INCOMING
SUPPLY FLOWING PRESSURE
OPERATING FLOWING PRESSURE
20 PSI 138 kPa
45 PSI/310 kPa
45 PSI/310 kPa
45 PSI/310 kPa
110°F/ 43°C
180°F/ 82°C
70°F
RISE
21kW
NO
BOOSTER
40°F
RISE
12kW
140°F/60°C
20PSI 138 kPa
20PSI 138 kPa
Fig. 5 - No booster may not require a PRV.
3/4" NPT
Inlet
MINIMUM INCOMING FLOW PRESSURE = 20-22 PSI/138-152 kPa
MINIMUM 3/4" NPT HOT WATER SUPPLY LINE.
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3 MG/L or LESS
INSTALL A 3/4" OR LARGER SHUT-OFF VALVE IN THE WATER SUPPLY LINE AS CLOSE TO THE
DISHWASHER AS POSSIBLE FOR SERVICING.
WATER SUPPLY CONNECTION IS LOCATED AT THE REAR OF THE DISHWASHER.
PRV
3/4" NPT
Inlet