EN - 11
WARNING: After the connections are
made, turn the tap on fully and check for
water leaks. Always turn o󰀨 the water inlet
tap after a wash program has nished.
An Aquastop water spout is available
with some models. Do not damage it
or allow it to become kinked or twisted.
2.4 Drain Hose (Model Depending)
Connect the water drain hose directly to
water drain hole or to the sink outlet spigot.
This connection should be minimum 50
cm and maximum 110 cm from oor that
dishwasher is placed.
IMPORTANT: Items will not wash
properly if a drain hose longer than 4
m is used.
0,5 - 1,1 m
2.5 Electrical Connection
WARNING: Your machine is set to
operate at 220-240 V. If the mains voltage
supply to your machine is 110 V, connect
a transformer of 110/220 V and 3000 W
between the electrical connection.
Connect the product to a
grounded outlet protected by a fuse
complying with the values in the “Technical
Specications” table”.
The earthed plug of the machine
must be connected to an earthed
outlet supplied by suitable voltage and
current.
In the absence of earthing
installation, an authorised
electrician should carry out an earthing
installation. In the case of use without
earthing installed, we will not be responsible
for any loss of use that may occur.
The plug on this appliance may
incorporate 13A fuse depending on the
target country. (For Example UK, Saudi
Arabia)