Error
Message
Possible causes What to do
No cookware or cookware not
suitable.
Replace the cookw
are.
ER03
Water or cookware on the glass
over the control area.
Clean the control area.
F1E
Connection between the display
board and the left mainboard fails
(the cooking zone which indicator
shows “E”).
1.Connection cable not correctly
plugged or defective.
2.Replace the mainboard.
F3E
Coil temperature sensor failure.
(in the cooking zone which
indicator shows “E”).
Replace the coil sensor.
F4E
Mainboard temperature sensor
failure. (in the cooking zone which
indicator shows “E”).
Replace the mainboard.
E1E
Temperature measured by the
sensor of the ceramic glass is too
high.
Please restart after the hob has
been cooled down.
E2 E
Temperature sensor of the IGBT is
too high.
Please restart after the hob has
been cooled down.
E3 E
Abnormal supply voltage (too
high).
Please inspect whether power
supply is normal. Switch on after
the power supply is normal.
E4 E
Abnormal supply voltage (too
low).
Please inspect whether power
supply is normal. Switch on after
the power supply is normal.
E5 E
Temperature sensor failure (in
the cooking zone which indicator
shows E”).
Connection cable not correctly
plugged or the assembly is
defective.
Please do not disassemble the unit by yourself to avoid any dangers and damages to
the induction hob.