Carel iJW handleiding
Handleiding
Je bekijkt pagina 76 van 104

76
ENG
iJW +0300103EN rel. 1.1 - 31.03.2025
Index
10.3 Alarm table
Display
code
Log
code (*)
Description
Delay
(default)
Icon
display
Alarm
relay
Buzzer Reset E ects on control
Afr 29 Frost protection Afd (1 min) YES YES YES Automatic Stop
compressor
AtS 30 Restart in pump down - NO NO NO Automatic -
CE 28 Confi guration write error - NO NO NO Automatic -
cht 17 High pre-alarm
Condenser temperature
- NO NO NO Automatic -
CHt 18 High conductivity
Condenser temperature
Acd (0 min) NO NO NO Manual Compressor shutdown
dA 14 Delayed alarm
from external contact
A7 (1 min) YES YES YES Automatic Compressor operation in duty
setting mode (par. A6);
dead band, lights and auxiliary
output OFF
dor 15 Door open Add (5 s) YES YES YES Automatic See
“Door management”
E1 1 Probe 1 faulty or disconnected - NO NO NO Automatic According to the
CONNECTIONS
E2 2 Probe 2 faulty or disconnected - NO NO NO Automatic
E3 3 Probe 3 faulty or disconnected - NO NO NO Automatic
E4 4 Probe 4 faulty or disconnected - NO NO NO Automatic
E5 5 Probe 5 faulty or disconnected - NO NO NO Automatic
Ed1 10 Defrost terminated
after maximum time
- NO NO NO Automatic -
Ed2 11 Defrost on second
evaporator terminated
after maximum time
- NO NO NO Automatic -
EHI 36 High temperature alarm
power supply
- YES YES YES Automatic -
ELO 37 Low pressure alarm
power supply
- YES YES YES Automatic -
Etc 9 Clock error - NO NO NO Manual Time bands disabled
GHI 19 Generic alarm
high threshold
GFA_De (0 s) YES YES YES Automatic -
GLO 20 Generic alarm
low threshold
GFA_De (0 s) YES YES YES Automatic -
HA 21 Type HA HACCP alarm
(high temp. during operation)
- NO NO NO Manual -
HF 22 Type HF HACCP alarm
(high temp. after blackout)
- NO NO NO Manual -
HI 24 High temperature Ad (120 s) YES YES YES Automatic -
IA 13 Immediate alarm
from external contact
- YES YES YES Automatic Compressor operation
in duty setting mode (par. A6);
dead band OFF
LO 23 Low temperature Ad (120 s) YES YES YES Automatic -
LP 32 Low pressure - YES YES YES Semi-auto-
matic
Compressor shutdown
MAn 38 Output status overridden
in manual mode
- YES YES YES Automatic -
Pd 26 Maximum time
Pump down
- YES YES YES Automatic -
rE 12 Control probe
faulty or disconnected
- YES YES YES Automatic Compressor operation
in duty setting mode (par. c4);
dead band OFF
rSF 31 Refrigerant leak alarm - YES YES YES Manual Switch off all
actuators
SF 27 Confi guration not completed
correctly
- NO NO NO Manual -
SrC 35 Maintenance request - YES YES YES Manual -
Tab. 10.b
(*) This is the code used to record and display the alarm in the Applica app.