1.Insertfromoutsidetheroomcableintoleftside of thewall
hole, in which the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable
making a loop.
When connecting the cable, conrm the terminal number of indoor and
outdoor units carefully. If wiring is not correct, proper operation can not
becarriedoutandwillcausedefect.
Insertthecablefromtheback
ƽ
side of the unit, then pull it out
on the front side.
Loosen the screws and insert
ƽ
the cable ends fully into
terminal block, then
tighten the screws.
Pull the cable slightly to
ƽ
make sure the cables have
been properly inserted and
tightened.
After the cable connection,
ƽ
never fail to fasten the connected cable with the
wiring cover.
When connecting the cable after installing the indoor unit
When connecting the cable before installing the indoor unit
Note:
To Outdoor unit
Code
indication
Trouble description
Analyze and diagnose
E1
E2
E4
E7
E14
Heat-exchange
sensor failure
Indoor EEPROM
error
Communication
fault between
indoor and outdoor
units
Indoor fan motor
malfunction
Operation halt due to breaking
of wire inside the fan motor;
Operation halt due to breaking
of the fan motor lead wires;
Detection error due to faulty
indoor unit PCB;
Indoor unit- outdoor unit signal
transmission error du
e to wiring
error;
Faulty PCB;
Faulty EEPROM data;
Faulty EEPROM;
Faulty PCB;
Faulty connector connection;
Faulty thermistor;
Faulty PCB;
Room temperature
sensor failure
The power source must be exclusively used for air
ƽ
conditioner.
In the case of installing an air conditioner in a moist place,
ƽ
please install
an ea
For installation in other places, use a circuit breaker as far
ƽ
as possible.
Pipecuttingiscarriedoutwith a pipecutterandbursmust beremoved.
After inserting the are nut, aring work is carried out.
Power Source Installation
Cutting and Flaring Work of Piping
FlaretoolforR410A Conventionalare tool
Clutch-type clutch-type(Rigid-type) Wing-nut type (Imperial-type)
A 0~0.5mm 1.0~1.5mm 1.5~2.0mm
rth leakage breaker.
Lean
Damage of are Partial Too outside
Correct Incorrect
On Drainage
It becomes
high midway.
The gap with the
ground is too small.
There is the bad
smell from a ditch
It waves.
The end is imm-
ersed in water.
Pleaseinstallthedrainhosesoastobedownwardslopewithoutfail.
Please don’t do the drainage as shown below.
ƽ
ƽ
Please pour water in the drain pan of the indoor unit, and
ƽ
is carried out surely to outdoor.
In case that the attached drain hose is in a room, please
ƽ
apply heat
insulation
to
Less than
5cm
conrm that
drainage
it without fail.
Crack
Indoor unit
CheckItemsforTestRun
Gasleakfrompipeconnecting?
Heat insulation of pipe connecting?
Are the connecting wirings of indoor and outdoor rmly
Is the connecting wiring of indoor and outdoor rmly xed?
Is drainage securely carried out?
Is the earth line securely connected?
Is the indoor unit securely xed?
Is power source voltage abided by the code?
Is there any noise?
Is the lamp normally lighting?
Arecoolingandheating(wheninheatpump)performednormally?
Is the operation of room temperature regulator normal?
Please kindly explain to our customers how to
operate
through the instruction manual.
inserted to the terminal block?
Ƶ
Put check mark
in boxes
Flare tooling die
1.Cut pipe
2.Remove burs
3.Insert the are nut
4.Flare pipe
ƽ
ƽ
On Drainage
Check for Installation and Test Run
Connecting wiring
4G1.0mm
2
1. If the supply cord is damaged, it must be replaced by the manufacturer
or its service agent or a similar qualied person. The type of connecting
wire is H07RN-F.
2. IfthefuseonPCboardisbrokenpleasechangeitwiththe
type of
T.3.15A/250VAC (Indoor).
3. Thewiringmethodshouldbeinlinewiththelocalwiringstandard.
4. After installation, the power plug should be easily reached.
5. A breakershouldbeincorporatedinto xed wiring. The breaker should
be all-pole switch and the distance between its two contacts should be
not less than 3mm.
6. AM35TK12-IU Connecting wiring
4G1.5mm
2
9

Bekijk gratis de handleiding van Candy CY-12TAIN, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkCandy
ModelCY-12TAIN
CategorieAirco
TaalNederlands
Grootte5958 MB

Caratteristiche Prodotto

Kleur van het productWit
Ingebouwd displayJa
TimerJa
SoortBinneneenheid airconditioning
GebruikershandleidingJa