Troubleshooting
Problem Possible cause Possible solution
Acoustic alarm,
LED flash at interval
(1 time / 1 sec).
The alarm code is
E10.
The appliance does
not fill with water.
Water tap is closed.
Open the water tap.
Water inlet hose has a kink or
a bend.
Make sure that the position of
the hose is correct.
In case of aqua-stop system:
water protection is triggered;
the marker (C) is red.
The hose must be replaced.
Filter in the water inlet hose
is clogged.
Clean the filter at the inlet
hose connections at tap and
the rear of the appliance.
Water inlet is clogged. Check water flow from tap.
Water pressure is too low.
Contact your local water
authority.
Acoustic alarm,
LED flash at interval
(3 times / 1 sec)
Leak:
The drain
pump runs permanently!
Anti- flood device is on:
There are water leakages in
the appliance.
The water inlet valve is
open and blocked.
The drainage is blocked.
1.Close the water tap.
2.Disconnect appliance from
power supply.
2.Contact Service.
2.Contact Service.
Error codes on the display
All other Alarmcodes:
1. Note Alarmcode
2. Contact Service ; refer to CUSTOMER SERVICE
Note: Whenever Error is solved
switch off the appliance and
restart the programm.
The alarm code is
E30.
29
E40
Flowmeter alarm
1.Long press the power
button to shut down or
unplug the power cord
1.Long press the power
button to shut down or
unplug the power cord
E50
Display board
communication alarm