Candy C6GGGFC2TN-ALG handleiding

52 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 18 van 52
1818
LUBRICATION OF THE GAS TAPS
In case of di󰀩culty in the gas taps operation, call Service.
IMPORTANT
All intervention regarding installation and maintenance of the appliance must be
fullled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Oven 4,20
Grill 3,90
GAS MAINTENANCE
Some models - for the gas category check the data label attached on the appliance
TABLE FOR THE CHOICE OF THE INJECTORS - Cat: I 3+
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
LPG
G30 (28-30 mbar)
G31 (37 mbar)
Ø injector
[1/100 mm]
Ring opening [mm]
Oven 2,20 0,80 70 Fully open (*)
Grill 1,95 - 70 2 (*)
(*) = Reference value
TABLE FOR THE CHOICE OF THE INJECTORS
Cat: II 2H 3+
G30/G31
28-30/37 mbar
G20
20 mbar
Cat: II 2E 3+
G30/G31
28-30/37 mbar
G20/G25
20/25 mbar
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
Ø injector
[1/100 mm]
Ring
opening
[mm]
Ø injector
[1/100 mm]
Ring
opening
[mm]
Oven
2,20 0,80
70
Fully
open (*)
110 2 (*)
Grill
1,95 -
70 2(*) 105 2 (*)
(*) Reference value
Some models - for the gas category check the data label attached on the appliance

Bekijk gratis de handleiding van Candy C6GGGFC2TN-ALG, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkCandy
ModelC6GGGFC2TN-ALG
CategorieOven
TaalNederlands
Grootte5530 MB