Canarm HVA36T10750 handleiding

16 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 2 van 16
XB, HV, HVA, HVAR, ADD, ADDR, DDS, DDP, SXB, SADD
M0112_NOV 2020 Page 2 of 8www.CANARM.COM
Canarm Ltd. - Corporate Head Office 2157 Parkedale Avenue, PO Box 367 Brockville, Ontario Canada K6V 5V6
Tel: (613) 342-5424 Fax: (613) 342-8437 hvacsales@canarm.ca www.canarm.com
WARNING: GUARDING SHOULD BE USED IF FANS ARE MOUNTED LOWER THAN
SEVEN FEET (2 METRES) OFF FLOOR OR GROUND LEVEL.
WARNING
Moving parts,
disconnect
power before
servicing.
!
INSTALLATION CONTINUED
10. Tighten all nuts, bolts and setscrews prior to fan start up (as some may have loosened during shipping).
11. On belt driven fans make sure that the belts are tensioned and aligned correctly.
12. Ensure that all protective guards and other safety devices are installed properly prior to fan start up.
STANDARD WIRING INSTRUCTIONS
1. A qualied electrician in accordance with all local and National Electrical Codes should do all wiring.
2. Lock off all power sources before any wiring is to be performed.
3. Leave enough slack in the wiring to allow for motor movement when adjusting the belt tension.
4. Excess wire must be restrained in order to prevent it from entering the shaft and propeller area.
5. Disconnect switches are recommended and should be located near the fan in order to, swiftly cut off power in
case of an emergency and maintain complete control of the power source.
6. Some motors may have to be removed in order to make the connections in the motor terminal box.
7. Follow the wiring diagrams on the motor nameplate.
1. Wall Fans
Extend the proper gauge wire to the fan motor.
Restrain excess wire from entering the shaft and propeller area
2. Wall Fans with Cabinets
Remove guard from cabinet.
Drill a hole through the cabinet at a convenient location and pull the wires
through (never wire through the guard).
Restrain excess wire from entering the shaft and propeller area
OPERATION
Pre Start Inspection
Lock out all power sources
Inspect all fasteners and set screws and tighten as required
Inspect belt alignment and tension
Conrm power source voltage and motor voltage are the same and that the motor is wired correctly
Rotate the fan blade to ensure that neither the fan blade nor the belts come into contact with the housing
Inspect the fan and the ductwork to ensure they are free of debris
Check to ensure that all guards and accessories are securely mounted
Check to be sure the propeller rotation is correct