Canarm CEPD140-4 handleiding

4 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 3 van 4
CONNECT ELECTRICAL WIRING
INSTALL GRILLE
3
Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the
wiring plate. Refer to the wiring diagram, and connect the wires as shown.
Install ceiling material to complete the ceiling construction.
Then, cut around the fan housing.
To attach the grille assembly to the fan housing. Pinch the grille springs on the
sides of the grille assembly, and position the grille into the housing with the grille
springs in the appropriate slots. Push the grille assembly towards the ceiling to
secure.
UNIT
BLACK (BLK)
SWITCH BOX
SWITCH
POWER SUPPLY
120V AC
GROUND (GRD)
WHITE (WHT)
FAN
RECEPTACLE
WIRE
PANEL
BROWN (BRN)
SERVICE PARTS
PART PART NAME Qty.
1
2
3
4
9
10
11
12
a
Housing
Wiring plate
Damper / Duct Connector
Screw
1
2
1
1
1
1
1
1
4
b Screw 5
c Screw 4
d Screw 6
Grille Assembly (includes part 2)
5
1
Blower
6
1
Blower Wheel
7
1
Motor Plate
8
4
Motor
Grille Spring
WARNING: Ensure that the fan is switched off from the supply
mains before replacing.
1
2
7
6
5
4
8
3
Wire Panel / Harness Assemblye
Hanger Bar Kit
Control Box
* Blower Assembly includes part 3, 4, 5, 6, 7, b, c
9
12
10
d
a
a
11
c
b
FAN
BRN
BLK
BLK
LINE
IN
WHT
WHT
GRD
UNITSWITCH BOX
GRD
SWITCH

Bekijk gratis de handleiding van Canarm CEPD140-4, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.